Land Lens
Get Started
Back to LandLens

Mixed Residential - Besant Nagar

Mixed

Urur, Velachery, Chennai

Plot Area 540 sq.m
Road Width 9.0m
Dimensions 18.0 × 30.0m
Type Regular
Units
Explain
1.500
Achievable FSI
810 sq.m
Max Built-up Area
14 m
Max Height
S+3/G+2
Floors

Planning Permission & Building Permit

Planning Permission CMDA
Chennai Metropolitan Development Authority
Issues Planning Permission for land use, FSI, setbacks within CMA
Building Permit Regional
GCC Headquarters
Buildings 5,000-10,000 sq.ft FSI area processed at GCC Headquarters Works Department

Special Clearances Required

TNCZMA
Tamil Nadu Coastal Zone Management Authority
Property within Coastal Regulation Zone
Zone: CRZ-II: building possible at the permitted FSI
Area Type Urban
Building Category Standard (≤19.5m)

Building Classification

Non High Rise, small development
Up to 16 dwelling units or 300 sq.m of commercial floor area and up to 14m: the small development table of TNCDBR 2019 Rule 35(1)(a) applies.
Relaxations That Apply
CC Exemption

Residential buildings up to 14m in height with up to 8 dwelling units OR up to 750 sq.m built-up area are exempt from Completion Certificate requirement for electricity, water, and sewerage connections.

TNCDBR 2019 Rule 20(1), as amended by G.O. Ms. No. 69 and 70 (2024)
Relaxed Setback Eligibility

G.O. 69 (2024) raised the upper setback tier of small developments from 12m to 14m: up to 7m, side 1m and rear Nil; above 7m up to 14m, side 1m or 1.5m by plot width and rear 1.5m.

G.O. Ms. No. 69 (2024), Rule 35(1) Table Amendment
Source: GCC Building Plan Approval Process, CMDA Delegation of Powers | Chief Engineer (SWM & TP), Works Department

Third-Party Certification Route

Not available on this site

The route does not apply here: the plot lies in Coastal Regulation Zone.

The owner, leaseholder or power of attorney holder applies online on the Tamil Nadu Single Window Portal for Planning Permission with a registered architect (Council of Architecture) or a Grade I engineer as the Third Party. They jointly certify the documents (geo-tagged site photographs, the sale deed, the patta or Town Survey Land Register, the approved or regularised layout or the pre-20.10.2016 deed, and a plan in .dxf or .dwg that passes the online scrutiny). On payment the approved plan and proceedings with a QR code are issued at once. The permit is valid five years and may be extended once by three years. At least 10% of these permits are picked at random each month for verification, and false certification is liable to revocation under sections 56 and 57 of the Town and Country Planning Act and prosecution under section 236 of the Bharatiya Nyaya Sanhita, 2023.

Source: TNCDBR 2019 Rule 2(105-D) to (105-F), Rule 6(1-B), Annexure XXVIII, inserted by G.O. (Ms) No. 179, H&UD, 07.10.2026

Property Location & Zone Overlays

Zone Overlays

Plot Dimensions (Your Input)

Side A (Front) 18.0m ROAD 9.0m
Side B (Right) 30.0m
Side C (Back) 18.0m
Side D (Left) 30.0m
Plot Area (Calculated) 540.00 sq.m
Frontage 18.0m
Depth 30.0m

Area = ((Side A + Side C) ÷ 2) × ((Side B + Side D) ÷ 2) = ((18.0 + 18.0) ÷ 2) × ((30.0 + 30.0) ÷ 2) = 540.00 sq.m

Required Setbacks

Rule 35(1)(a) setbacks, as amended by G.O. Ms. No. 69 (2024) for small developments up to 14m: up to 7m height, side 1m (one side on plots up to 9m wide, else either side) and rear Nil; above 7m, side 1m or 1.5m by plot width and rear 1.5m.
Front (A) (Road) 1.5m
Left (D) 1.5m
Right (B) 1.5m
Back (C) 1.5m

Plot and Setbacks as a Drawing

Take the plot, its roads, the setback line and each scenario's building into CAD or Google Earth. Every part sits on its own layer, in metres, with the building heights set, so the drawing starts from this report's figures.

DXF for CADAutoCAD, BricsCAD, LibreCAD or QGIS
KML for Google EarthNeeds the plot's place on the ground

This plot was entered as side lengths, which gives its shape but not where it lies or which way is north, so a map file would only be a guess. A KML is offered when the plot is read from a KML, KMZ or GeoJSON file at the plot step.

High-Rise Feasibility (>19.5m)

Not Eligible for High-Rise

One or more requirements not met

Road Width: 9m Minimum 12m required
Frontage: 18.0m Minimum 29m required
Depth: 30.0m Minimum 29m required

Development Scenarios

Showing: Normal Building + Normal FSI
Max FSI 1.500
Achievable FSI 1.500
Built-up Area 810 sq.m
Height 14 m
Floors S+3/G+2
Coverage 50%

Maximize building height with standard development norms

Setbacks:
Front: 3.25m Rear: 3.25m Side 1: 3.25m Side 2: 3.25m
Parking Requirements
Cars 9
Two-Wheeler 1
Visitor 1
Disabled 3
Parking Area(appx) 193 sq.m
1001 sqft 8 units
Plot Setback Buildable
Max FSI 1.500
Achievable FSI 0.844
Built-up Area 456 sq.m
Height 6 m
Floors S+1/G+0
Coverage 84%

Maximize ground floor area with fewer floors

Setbacks:
Front: 1.5m Rear: 0m Side 1: 1m Side 2: 1m
Parking Requirements
Cars 9
Two-Wheeler 1
Visitor 1
Parking Area(appx) 178 sq.m
1001 sqft 8 units
Plot Setback Buildable
Max FSI 1.500
Achievable FSI 1.500
Built-up Area 810 sq.m
Height 9 m
Floors S+2/G+1
Coverage 75%

Optimal balance for maximum total built-up area

Setbacks:
Front: 1.5m Rear: 1.5m Side 1: 1.5m Side 2: 1.5m
Parking Requirements
Cars 9
Two-Wheeler 1
Visitor 1
Parking Area(appx) 178 sq.m
1001 sqft 8 units
Plot Setback Buildable

Scenario Comparison

Parameter Max Height Max Coverage Max Builtup
FSI 1.500 1.500 1.500
Built-up Area 810 sq.m 456 sq.m 810 sq.m
Height 14m 6m 9m
Floors S+3/G+2 S+1/G+0 S+2/G+1
Coverage 50% 84% 75%
Charges - - -
Car Parking 9 9 9
Two-Wheeler 1 1 1
Parking Area(appx) 193 sq.m 178 sq.m 178 sq.m
Important Notes
  • Height Calculations: A high-rise needs a setback all around set by its height: 7.0m up to 30m, 8.0m to 36m, 9.0m to 51m, 10.0m to 57m, 11.0m to 63m, 12.0m to 69m, 13.0m to 75m, 14.0m to 81m, 15.0m to 87m, 16.0m above 87m (TNCDBR 2019 Rule 39(3), table substituted by G.O. (Ms) No. 194 of 26.10.2026). That table has no coverage limit. Above 87m it sets no further height limit; this report models up to 300m, and airport height clearance and the fire service decide the real ceiling. A non high-rise building is capped at 19.50m.
  • Minimum Building Size: Every high-rise scenario keeps a floor plate of at least 15m × 15m for two staircases, a fire lift and the core (National Building Code), so a high-rise needs at least 29m of frontage and depth after any road widening. TNCDBR 2019 itself sets no minimum plot for a high-rise.
  • FSI-Exempt Areas: Basement and stilt parking floors (with their stairs and lifts) and the stair and lift rooms on the terrace are excluded from FSI per TNCDBR 2019 Rule 29; balconies and habitable floors are counted.
  • Airport NOC: This location is in an airport height zone with a 85m height limit. A building taller than that needs an Airport Authority of India (AAI) NOC.
  • CRZ-II: building possible at the permitted FSI, on the conditions of the CRZ Notification, 2011, para 8 II: landward side of an existing road or authorised structures only, and the FSI at the 1991 level (1.5, or 2.25 for a high-rise on a road of 18m or more).

Plot Visualization

Plot Boundary
Setback Area
Buildable Area
Road

Environmental & Statutory Requirements

OSR (Open Space Reservation)

Not Required (Plot < 3000 sq.m)

Rainwater Harvesting

Required

Band (a) of Annexure XXII: Non High Rise building up to 14m (house or apartment up to Ground + 2 or Stilt + 3, not more than 16 dwelling units). Roof water led through a first flush cum pebble-sand filter (or a special filter) to a sump for use, the overflow diverted to the dug well if the plot has one, otherwise to a recharge well.

Rooftop Solar (PV)

Not Required

Solar power recommended but not mandatory

Sewage Treatment Plant

Not Required

Below the STP thresholds; connect to the public sewer, or where there is none provide a septic tank with up-flow filter (Rule 35(15)(b))

Completion Certificate

Not required for service connections

Residential up to 14m with ≤8 units or ≤750 sq.m, Rule 20(1)

Comprehensive Zone & Overlay Analysis

Infrastructure Availability

CMWSSB Metrowater CMWSSB connection not available. Alternative source required. (nearest 1.9km)
CMWSSB Sewage CMWSSB sewage nearby - may be extendable. (234.0m away)
High Tension (HT) Line Safe distance from high tension lines. (nearest: 22.0m)

Zoning & Planning Areas

Land Use Zoning Land Use Zone: Primary Residential
Continuous Building Area (CBA) Standard setback rules apply as per TNCDBR 2019.
Transit Oriented Development (TOD) Not within 500m of a Metro Rail, MRTS or suburban rail corridor (Rule 30(5)). (nearest: 1.5km)
Hill Area Conservation (HACA) Property is outside Hill Area Conservation boundary.
Wetland/Swamp Zone Property is outside protected wetland zones.

Environmental Overlays

Aquifer Recharge Zone No aquifer recharge restrictions apply.
Redhills Catchment Property is outside reservoir catchment area.
Coastal Regulation Zone (CRZ) CRZ-II: building possible at the permitted FSI. Conditions: (1) only on the landward side of an existing road, or of existing authorised structures. (2) the local planning rules apply, except the FSI, which stays at the 1991 level: 1.5, or 2.25 for a high-rise on a road of 18 m or more. (3) no building on the landward side of a new road built on the seaward side of an existing road. (4) an authorised building may be rebuilt at its existing FSI and without change in its present use. Source: CRZ Notification, 2011, para 8 II.
Building possible Landward side only FSI 1.5 (1991 level)
Eco-Sensitive Zone Property is outside eco-sensitive buffer zones.
Ramsar Site Property is outside Ramsar site buffer.

Height Restrictions

Airport Height Restriction Airport zone with 85m height limit. Your building (14m) is within the limit.

Proximity & Hazard Checks

Railway Proximity Adequate distance from railway boundary. (nearest: 2.2km)
Metro Rail Proximity No metro alignment restrictions apply. (nearest: 1.5km)
Water Body/Canal Adequate distance from mapped water bodies. Minor channels/vaikkals may not be in the official layer. (nearest: 840.0m)
Quarry Proximity Safe distance from quarry operations. (nearest: 11.5km)
Burial Ground Adequate distance from burial grounds. (nearest: 611.0m)
Road Widening No road widening proposals affect this property.
Flood Inundation Property is outside flood inundation zones.

Heritage & Cultural

ASI Monuments Property is outside ASI monument protection zones.

Industry & Pollution

Industry Zone Property is in non-industrial zone. (nearest: 2.8km)

NOCs & Clearances Required (TNCDBR 2019)

1 Required 2 Verify
Environmental & Coastal 1
DCZMA NOC
District/Tamil Nadu Coastal Zone Management Authority
Condition: Within 500m of High Tide Line (CRZ Area)
Why: Property is in the coastal zone mapped as CRZ-2
Tamil Nadu's approved Coastal Zone Management Plan, CRZ Notification, 2011, para 8

Manual Verification Required: Some NOCs require verification based on actual property documents and local conditions. Consult with local authorities for definitive requirements.

Disclaimer: This analysis is based on TNCDBR 2019 with its amendments up to G.O. (Ms) No. 194 of 26.10.2026, and government planning parameters. Actual approvals depend on site-specific conditions and local authority requirements. Consult a registered architect or town planner for project-specific advice. For expert guidance on building approvals and compliance, click here.

Location-based checks (HT lines, water bodies, CRZ, airport, eco-sensitive zones, etc.) are computed from the property's mapped coordinate against third-party and government GIS data, so the distances and zone boundaries shown are indicative. Confirm critical findings on-site or with the concerned department.
From report to drawings

Want this built? Talk to us on WhatsApp.

Fast professional designs, planning approvals, the permits and NOCs this report lists, and more, from the team behind LandLens. Message +91 99961 29996 with your report reference VRE-BS-99999 and we pick it up from here.

WhatsApp +91 99961 29996 Usually answered within the hour, 9 am to 9 pm