primary law

Tamil Nadu Government Gazette, No. 16, Part VI, Section 1 (16 VI 1 v2)

The Government of Tamil Nadu published Tamil Nadu Government Gazette No. 16, Part VI, Section 1, on 28 April 2010. It includes Notification No. VI(1)/166/2010, under reference Roc. No. 7914/10/Special Cell, declaring 7.17 acres in specified survey numbers of Kalavakkam Village, Chengalpattu Taluk, as a multistoried building area for residential construction, subject to planning, safety, accessibility and environmental conditions, and also records the winding up or cancellation of several cooperative societies.

Category
Gazette notifications
Pages
7
Status
In force
Open the source document The official copy, as published. Opens in a new tab.
Source document Preview loads as you scroll

What the Gazette covers

Tamil Nadu Government Gazette No. 16, Part VI, Section 1, published by the Government of Tamil Nadu on 28 April 2010, contains public notifications issued by heads of departments. The supplied text covers a residential multistoried building area declaration in Kalavakkam Village and decisions concerning industrial and milk supply cooperative societies.

Kalavakkam residential development

Notification No. VI(1)/166/2010, under reference Roc. No. 7914/10/Special Cell, declares 7.17 acres in Survey Numbers 159/2B, 192/1, 194-1,2,3, 195/1,2,3 and 196 of Kalavakkam Village, Chengalpattu Taluk, as a multistoried building area for residential construction under the Tamil Nadu Multistoried and Public Building Rules, 1973.

The notification requires the following when building plans are cleared:

  • The building must comply with Floor Space Index, plot coverage and other applicable parameters.
  • The applicant must obtain necessary clearances and No Objection Certificates from the Director of Town and Country Planning, Highways Department, Traffic Police Department, Fire Service Department, Chennai Regional Advisory Committee, Airport Authority, Microwave Authority and Tamil Nadu Pollution Control Board.
  • Environmental Impact Assessment clearance must be obtained from the Ministry of Environment and Forest Department, Government of India, under the latest Central Government notification, and submitted to the relevant authority.
  • The structure must be earthquake resistant and designed by a Registered Professional Structural Engineer, who must sign all plans.
  • The design must follow NBC 2005, supported by an undertaking from the developer.
  • Access ramps, a ramp ratio of 1:10 and parking near the entrance must be provided for physically challenged persons.
  • Suitable drainage facilities and a sewage treatment plant must be provided within the complex.

Property buyers and professionals should note that the declaration applies only to the listed survey numbers. It also makes the proposed development subject to multiple approvals and plan clearance conditions.

Cooperative society decisions

The Industries Commissioner and Director of Industries and Commerce and Registrar of Industrial Cooperative Societies ordered the winding up of several transport and production cooperative societies in Chennai, Tiruchirappalli and Cuddalore, and appointed official liquidators.

The Gazette also records cancellation of registration on 29 March 2010 for identified milk supply cooperative societies in Namakkal District, including societies at Komarapalayam, Semmadaipalayam, Namakkal, Valayapatty, Velur and Chinna Elachipalayam.

This summary is generated from the source document to help you find what is relevant. The PDF above is authoritative. For advice on your own property, use LandLens One or speak to a qualified professional.

Common questions

Does the Kalavakkam declaration apply to every property in the village?

No. Notification No. VI(1)/166/2010 applies to 7.17 acres within the survey numbers specifically listed in the notification.

Does the declaration remove the need for building approvals?

No. The applicant must obtain the listed clearances and No Objection Certificates, comply with planning parameters and submit the required environmental clearance.

What accessibility measures are required for the residential building?

The plans must provide a ramp to the lift room, show a ramp ratio of 1:10 and provide sufficient parking near the entrance for physically challenged persons.

What structural safety requirements apply to the proposed building?

The building must be earthquake resistant, designed and signed off in the plans by a Registered Professional Structural Engineer, and designed based on NBC 2005.