Declaration of Multistoried Building Area for Construction of I.T. Buildings at Veerapuram Village and Thenmalpakkam Village in Chengalpet Taluk, Kancheepuram District

The Government of Tamil Nadu, through the Town and Country Planning notifications issued by Heads of Departments, published Notification No. VI(1)/89/2013 in the Tamil Nadu Government Gazette dated 6 February 2013. It declares specified survey lands in Veerapuram Village and Thenmalpakkam Village, stated to cover 58.87 acres, as a multistoried building area for construction of information technology buildings, subject to planning, safety, environmental and infrastructure conditions.

Category
Gazette notifications
Pages
13
Status
In force
Open the source document The official copy, as published. Opens in a new tab.
Source document Preview loads as you scroll

What the notification does

Notification No. VI(1)/89/2013 declares specified survey lands in Veerapuram Village and Thenmalpakkam Village, Veerapuram Panchayat, Kattankolathur Panchayat Union, Chengalpet Taluk, Kancheepuram District, as a multistoried building area for information technology buildings. The declared area is stated as 58.87 acres and includes land in an approved layout identified as LP/DTCP No. 108/2010, Plot No. TPI.

The declaration applies under the Tamil Nadu Multistoried and Public Building Rules, 1973 and related instructions. It does not by itself grant building plan approval.

Who may be affected

Notification No. VI(1)/89/2013 is relevant to owners, buyers, developers, architects and structural engineers dealing with the listed survey lands. A person checking property in either village should compare the property survey number with the detailed list in the Gazette rather than assume that the whole village is covered.

The notification is especially relevant where the proposed use is a multistoried information technology building. Building plans must meet the stated conditions and obtain required clearances.

Main conditions

The declaration requires compliance with conditions including:

  • Floor Space Index, plot coverage and other multistoried building requirements must follow the applicable rules and instructions.
  • Clearances or no objection certificates must be obtained from the relevant town planning, highways, traffic police, fire service, airport, microwave and pollution control authorities.
  • Environmental impact assessment clearance must be obtained from the Ministry of Environment and Forest Department, Government of India, where required by the latest Central Government notification.
  • The structure must be earthquake resistant and designed by a registered professional structural engineer.
  • Design must follow the National Building Code 2005, supported by an undertaking from the developer.
  • Ramps, accessible parking and sufficient lifts must be provided for persons with disabilities.
  • Drainage, a sewage treatment plant, wastewater recycling arrangements and rainwater harvesting must be provided.
  • Fire extinguishers, emergency escape stairs and lightning arresters are required.
  • Solar energy arrangements and adequate parking must be included.
  • The applicant must provide details of drinking water and other water supply arrangements.
  • A stability affidavit signed by the architect, owner and structural design engineer must confirm soil testing and structural safety.

Practical check before purchase or development

A buyer or developer should verify the exact survey number, approved layout reference and permitted proposal with the relevant planning authority. The declaration allows the area to be considered for multistoried information technology buildings, but the required approvals and no objection certificates remain necessary.

This summary is generated from the source document to help you find what is relevant. The PDF above is authoritative. For advice on your own property, use LandLens One or speak to a qualified professional.

Common questions

Does the declaration cover all land in Veerapuram and Thenmalpakkam villages?

No. Notification No. VI(1)/89/2013 applies only to the survey lands listed in the Gazette.

Can I construct a multistoried information technology building without separate approval?

No. The declaration requires building plan compliance and clearances or no objection certificates from the relevant authorities.

What structural safety requirements apply to a proposed building?

The building must be earthquake resistant, designed by a registered professional structural engineer and based on the National Building Code 2005. A stability affidavit signed by the architect, owner and structural design engineer is also required.

Are environmental and water management measures required?

Yes. The conditions include environmental clearance where required, drainage, a sewage treatment plant, wastewater recycling certification, rainwater harvesting and detailed water supply arrangements.